 <titleInfo>
  <title>Perancangan Magnetic Field Probes untuk Pengujian Radiated Emission</title>
 </titleInfo>
 <name type="Personal Name" authority="">
  <namePart>Nurul Azanna</namePart>
  <role>
   <roleTerm type="text">Primary Author</roleTerm>
  </role>
 </name>
 <name type="Personal Name" authority="">
  <namePart>1520301047</namePart>
  <role>
   <roleTerm type="text">Additional Author</roleTerm>
  </role>
 </name>
 <typeOfResource manuscript="no" collection="yes">mixed material</typeOfResource>
 <genre authority="marcgt">bibliography</genre>
 <originInfo>
  <place>
   <placeTerm type="text">Pekanbaru</placeTerm>
   <publisher>Pustaka Politeknik Caltex Riau</publisher>
   <dateIssued>2019</dateIssued>
  </place>
 </originInfo>
 <language>
  <languageTerm type="code">id</languageTerm>
  <languageTerm type="text">Indonesia</languageTerm>
 </language>
 <physicalDescription>
  <form authority="gmd">Text</form>
  <extent>xiii, 69 hlm.; 21 cm</extent>
 </physicalDescription>
 <note>Science and technology are growing so rapidly that electronic&#13;
equipment and instruments are widely used, but the emission of&#13;
electromagnetic radiation is also introduced and occurs at the&#13;
same time so that it continues to potentially cause health problems.&#13;
One effective way to detect EMI emissions is by conducting Precompliance testing using a tool in the form of probes, namely&#13;
Magnetic Field Probes. The role of pre-compliance testing&#13;
provides an initial indication of whether the equipment might meet&#13;
requirements when Full-compliance testing is carried out. When&#13;
measuring using M1 Loop - H Field and Probe 1 twist and Probe&#13;
2 windings as is known from this final project (TA) it is expected&#13;
that Magnetic Field Probes sensitivity is above -68 dBm. After&#13;
measurement using M1 Loop - H Field and Probe 1 Windings and&#13;
Probe 2 Windings as expected above -68 dBm which is -26,36 dBm.&#13;
When testing it is known that the sensitivity of Probe 2 coil is better&#13;
than Probe 1 coil. This is because the number of turns used is&#13;
different, which is designed by using two turns where the magnetic&#13;
field generated by one coil is reinforced by other turns. The&#13;
magnitude of the magnetic field depends on the number of turns,&#13;
the more the number of turns, the greater the value of the magnetic&#13;
field produced. Then, electronic devices are used as objects for&#13;
measuring emission of electromagnetic radiation, namely EM&#13;
Demo Board, PABX and Led Driver. The standard used is EN&#13;
55011 (Standard CISPR11) with a frequency range of 30 MHz to 3&#13;
GHz.&#13;
Keywords: Loop antenna, Electromagnetic Induction, Magnetic&#13;
fields, Magnetic fields probes, Pre-compliance, Full-Compliance,&#13;
Radiated Emission, Standards EN 55011 (CISPR11).</note>
 <note type="statement of responsibility"></note>
 <subject authority="">
  <topic>PA Teknik Elektronika Telekomunikasi</topic>
 </subject>
 <classification>PA TET</classification>
 <identifier type="isbn"></identifier>
 <location>
  <physicalLocation>Politeknik Caltex Riau Politeknik Caltex Riau</physicalLocation>
  <shelfLocator>PA TET</shelfLocator>
  <holdingSimple>
   <copyInformation>
    <numerationAndChronology type="1">PA1520301047</numerationAndChronology>
    <sublocation>Perpustakaan PCR (R)</sublocation>
    <shelfLocator></shelfLocator>
   </copyInformation>
  </holdingSimple>
 </location>
 <slims:digitals>
  <slims:digital_item id="6659" url="" path="KP_PA/POSTER/PA1520301047_poster_pa.jpg" mimetype="image/jpeg">Poster - PERANCANGAN MAGNETIC FIELD PROBES UNTUK PENGUJIAN RADIATED EMISSION</slims:digital_item>
 </slims:digitals>
 <recordInfo>
  <recordIdentifier>10681</recordIdentifier>
  <recordCreationDate encoding="w3cdtf">2019-07-01 00:00:00</recordCreationDate>
  <recordChangeDate encoding="w3cdtf">2019-11-04 16:20:10</recordChangeDate>
  <recordOrigin>machine generated</recordOrigin>
 </recordInfo>
</mods>