<?xml version="1.0" encoding="UTF-8" ?>
<modsCollection xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.loc.gov/mods/v3" xmlns:slims="http://slims.web.id" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-3.xsd">
<mods version="3.3" id="11199">
 <titleInfo>
  <title>Alat Pengukur Tekanan Darah Otomatis Menggunakan Sensor MPX2100DP (Hardware)</title>
 </titleInfo>
 <name type="Personal Name" authority="">
  <namePart>Firman Santiya Budi</namePart>
  <role>
   <roleTerm type="text">Primary Author</roleTerm>
  </role>
 </name>
 <name type="Personal Name" authority="">
  <namePart>1520401020</namePart>
  <role>
   <roleTerm type="text">Additional Author</roleTerm>
  </role>
 </name>
 <typeOfResource manuscript="no" collection="yes">mixed material</typeOfResource>
 <genre authority="marcgt">bibliography</genre>
 <originInfo>
  <place>
   <placeTerm type="text">Pekanbaru</placeTerm>
   <publisher>Pustaka Politeknik Caltex Riau</publisher>
   <dateIssued>2019</dateIssued>
  </place>
 </originInfo>
 <language>
  <languageTerm type="code">id</languageTerm>
  <languageTerm type="text">Indonesia</languageTerm>
 </language>
 <physicalDescription>
  <form authority="gmd">Text</form>
  <extent>xi, 42 hlm.; 21 cm</extent>
 </physicalDescription>
 <note>Alat pengukur tekanan darah ini merupakan instrumentasi medis yang dirancang&#13;
untuk mengukur tekanan darah yang merupakan hasil dari aktivitas pemompaan&#13;
jantung yang berlangsung secara kontraksi dan relaksasi. Perancangan dan pembuatan&#13;
alat pengukur tekanan darah otomatis terdiri dari pompa otomatis, mikrokontroler&#13;
arduino, sensor MPX2100DP, pulse sensor, penguat rangkaian, LCD, motor DC,&#13;
selenoid valve dan relay. Sensor tekanan MPX2100DP sebagai pengukur tekanan&#13;
darah juga dapat menentukan nilai dari tekanan sistolik dan diastolik menggunakan&#13;
metode oscillometry dan juga dengan pencaria nilai MAP (Mean Arteriar Pressure)&#13;
Kata kunci: Tekanan darah, Sensor MPX2100DP, Arduino, Oscillometry, MAP</note>
 <note type="statement of responsibility"></note>
 <subject authority="">
  <topic>PA Teknik Elektronika</topic>
 </subject>
 <classification>PA TE</classification>
 <identifier type="isbn"></identifier>
 <location>
  <physicalLocation>Politeknik Caltex Riau Politeknik Caltex Riau</physicalLocation>
  <shelfLocator>PA TE</shelfLocator>
  <holdingSimple>
   <copyInformation>
    <numerationAndChronology type="1">PA1520401020</numerationAndChronology>
    <sublocation>Perpustakaan PCR</sublocation>
    <shelfLocator></shelfLocator>
   </copyInformation>
  </holdingSimple>
 </location>
 <slims:digitals>
  <slims:digital_item id="9030" url="" path="KP_PA/POSTER/PA1520401020_poster_pa.png" mimetype="image/png">Poster - Alat Pengukur Tekanan Darah Otomatis Menggunakan Sensor MPX2100DP (Hardware)</slims:digital_item>
  <slims:digital_item id="9172" url="" path="KP_PA/VIDEO/PA1520401020_video_pa.mp4" mimetype="video/mp4">Video - Alat Pengukur Tekanan Darah Otomatis Menggunakan Sensor MPX2100DP (Hardware)</slims:digital_item>
 </slims:digitals>
 <recordInfo>
  <recordIdentifier>11199</recordIdentifier>
  <recordCreationDate encoding="w3cdtf">2019-09-06 00:00:00</recordCreationDate>
  <recordChangeDate encoding="w3cdtf">2020-01-10 13:56:35</recordChangeDate>
  <recordOrigin>machine generated</recordOrigin>
 </recordInfo>
</mods>